| RED-ATX300 (300W Redundant ATX) |
 |
 |
Hot swap redundant ATX power supply prevents downtime at super price. Each ATX power
supply is a 300W, six output unit with remote on/off, built-in EMI filter, and UL, CSA,
TUV, CE approvals. Comes with two ball-bearing fans, long 30"+ reach output connectors
and monitor cabling, power fault alarm with reset, and keylock for each power unit. Easy
setup with several ways to monitor system power status. AC inlet is detachable from 24"
cable for flexible installation on any case. MTBF greater than 100,000 hours. Peripheral
to P4 adapter is included ! Manufacturer p/n EPR-2309S, made by Etasis for
MACASE. Power modules p/n EPR-308.
|
|
|
|
| Connectors |
 |
| This power unit has (1) 20 pin ATX connector, (1) peripheral
to ATX12V adapter, (8) peripheral power connectors, and (2) floppy drive connectors. |
|
| 20 pin ATX1 |
ATX12V2 |
Peripheral3 |
Floppy4 |
|
|
|
|
|
Connector notes:
1MOLEX 39-01-2200 or equivalent. Pin 11 also contains +3.3V Sense.
2MOLEX 39-29-9042 or equivalent.
3AMP 1-480424-0 or equivalent. 4AMP 171822-4 or equivalent.
|
| Specifications |
| Manufacturer |
Etasis |
Model |
EPR-2309S |
| Type |
Redundant ATX |
Warranty |
1 year |
| Dimensions |
153.4L x 184W x 176.5H mm |
Dimensions US |
6.04" x 7.24" x 6.94" |
| Safety |
UL, CSA, TUV, CE |
Efficiency |
65% minimum |
| Cooling |
Two 12V internal DC fans, each 35 CFM minimum |
|
| AC Input |
| Voltage |
Max current |
Frequency |
Protection |
| 115/230VAC |
7/4 A |
47-63 HZ |
Internal fuse |
| AC Input is switch selectable between 115V
(90-132V) and 230V (180-264V). |
|
| DC Outputs |
| Voltage |
Max Current |
Min Current |
Max Ripple |
Load |
Line |
Cross |
| +3.3V |
15 A |
0.0 A |
+1% |
+5% |
+1% |
+5% |
| +5V |
30 A |
3.0 A |
+1% |
+5% |
+1% |
+5% |
| +12V |
12 A |
1.0 A |
+1% |
+5% |
+1% |
+5% |
| -5V |
0.5 A |
0.0 A |
+1% |
+10% |
+1% |
+10% |
| -12V |
0.5 A |
0.0 A |
+1% |
+10% |
+1% |
+10% |
| +5VSB |
1.0 A |
0.0 A |
+1% |
+5% |
+1% |
+5% |
| Notes: (1) +3.3V and +5V combined not to exceed 150W,
(2) Load, Line, and Cross refer to regulation, (3) Output Voltage Hold Time is 20mS at full
load, (4) Overvoltage protection for +5V trips between 5.6V - 6.9V, +3.3V trips between
3.7V - 4.5V, and +12V trips between 13.6V to 15.6V, (5) Over power protection trips between
110% to 130% of total output. |
|
|