| Micro ATX-180V (180W SFX12V) |
 |
 |
This Micro ATX power supply is a 180W, SFX Form Factor, six output unit with remote
on/off, energy star certification, UL, CSA, CB, TUV, NEMKO and CE approvals. Airflow
drawn out of case by 80mm internal fan. AC input is positioned on long side of power
supply. Compliant with Intel P4 SFX12V Power Design Guide 2.0 and AMD Athlon
requirements. Includes optional -5V output for backward compatibility with legacy systems.
Upgrade for Fortron/Source FSP150-50NI, FSP150-50CI,
Ilssan ISP 120S, ISP 120SI, Bestec ATX-100-5,
ATX-151, ATX-1523D, ATX-1523F, HIPRO
HP-K1603A3, HP-K1507A3C, HP-K1363A3, Delta
DPS-145PB-111, DPS-120AB A, DPS-120AB-1,
DPS-111AB-A, HeroIchi HEC-145FC and others. Manufacturer p/n
FSP180-50NIV.
|
|
|
|
| Connectors |
 |
| This power unit has (1) ATX connector, (1) ATX12V
connector, (3) peripheral power connectors, and (1) floppy drive connector. |
|
| 20 pin ATX1 |
ATX12V2 |
Peripheral3 |
Floppy4 |
|
|
|
|
|
Connector notes:
1MOLEX 39-01-2200 or equivalent. Pin 11 also contains +3.3V Sense.
2MOLEX 39-29-9042 or equivalent
3AMP 1-480424-0 or equivalent. 4AMP 171822-4 or equivalent.
|
| Specifications |
| Manufacturer |
Fortron/Source |
Model |
FSP180-50NIV |
| Type |
SFX12V |
Warranty |
1 year |
| Dimensions |
125L x 100W x 63.5H mm |
Dimensions US |
4.9" x 3.9" x 2.5" |
| Safety |
UL, CSA, TUV, NEMKO, CB, CE |
Efficiency |
65% minimum |
| Reliability |
> 100K hours at 25°C ambient conditions. |
|
| AC Input |
| Voltage |
Max current |
Frequency |
Protection |
| 115/230VAC |
6/3 A |
47-63 HZ |
Internal fuse |
| AC Input is switch selectable between 115V (95-132V) and 230V (180-264V). |
|
| DC Outputs |
| Voltage |
Max Current |
Min Current |
Max Ripple |
Load |
Line |
Cross |
| +3.3V |
16.7 A |
0.0 A |
50 mVpp |
+5% |
+5% |
+5% |
| +5V |
16 A |
1.0 A |
50 mVpp |
+4% |
+5% |
+4% |
| +12V |
10 A |
0.2 A |
120 mVpp |
+5% |
+5% |
+5% |
| -12V |
0.3 A |
0.0 A |
120 mVpp |
+10% |
+5% |
+5% |
| -5V |
0.2 A |
0.0 A |
120 mVpp |
+10% |
+5% |
+5% |
| +5VSB |
2.0 A |
0.0 A |
50 mVpp |
+5% |
+5% |
+5% |
| Notes: (1) Load, line, and cross refer to regulation,
(2) Output Voltage Hold Time is 16mS. |
|
|